BMVDY - POTASSIUM DICHROMATE SOLUTION 0.1N, SP1701
- MSDS: BMVDY
- Manufacturer: FISHER SCIENTIFIC CHEMICAL DIV
- Product Name: POTASSIUM DICHROMATE SOLUTION 0.1N, SP1701
- National Stock Number: 6810-00N027725
Product Identification
Product ID:POTASSIUM DICHROMATE SOLUTION 0.1N, SP1701
MSDS Date:10/07/1991
FSC:6810
NIIN:00N027725
MSDS Number: BMVDY
Responsible Party
FAIR LAWN, NJ 07410
US
Emergency Phone: 201-796-7100/800-424-9300(CHEMTREC)
Info Phone: 201-796-7100 OR 201-796-7523
Cage: 1B464
Contractor
Telephone: 201-796-7100
Cage: 1B464
Ingredients
DICHROMIC ACID, DIPOTASSIUM SALT; (POTASSIUM DICHROMATE)
CAS: 7778-50-9
RTECS: HX7680000
Fraction By Weight: 44%
OSHA PEL C,0.1 MG/M3 CRO3
ACGIH TLV: 0.5 MG CR/M3; 9293
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: 99.56%
Hazards
LD50 LC50 Mixture:LD50:(ORAL,MOUSE)190 MG/KG.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:CORROSIVE. TARGET EFFECTS:SKIN
SENSITIZER. ACUTE:EYE:NO DATA AVAILABLE. INHAL:MAY BE IRRITATING.
SKIN:MAY BE IRRITATING. INGEST:TOXIC BY INGESTION. MAY CAUSE
GASTROINTESTINAL IRRITATION. CHRONIC:NO DA TA AVAILABLE.
Explanation of Carcinogenicity:CHROMIUM COMPOUNDS:GROUP 1 (NTP),
(IARC).
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHAL:REMOVE TO FRESH AIR IMMED. IF BRTHG STOPPED, GIVE ARTF
RESP. MAINTAIN AIRWAY & BLOOD PRESS & GIVE O*2. KEEP WARM & AT
REST. GET MD IMMED. SKIN:REMOVE CONTAMD CLTHG & SHOES IMMED. WASH
AFFECTED A REA W/SOAP/MILD DETERGENT & LG AMTS OF WATER UNTIL NO
EVID OF CHEM REMAINS (APPROX 16-20 MIN). GET MD IMMED. EYE:WASH
IMMED W/LG AMTS OF WATER/NORM SALINE, LIFTING LIDS, UNTIL NO EVID
OF (SUPP DATA)
Fire Fighting
Extinguishing Media:DRY CHEMICAL, CARBON DIOXIDE, WATER SPRAY OR
REGULAR FOAM. FOR LARGER FIRES:USE WATER SPRAY, FOG OR REGULAR
FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROTCTIVE
EQUIP . NO ACUTE HAZARD. MOVE CONTAINER FROM FIRE AREA IF POSSIBLE.
AVOID BRTHG VAPORS/DUSTS. KEEP UPWIND.
Unusual Fire/Explosion Hazard:NEGLIGIBLE FIRE HAZARD WHEN EXPOSED TO
HEAT OR FLAME.
Accidental Release
Spill Release Procedures:ABSORB W/VERMICULITE OR OTHER SUITABLE
MATERIAL. PLACE IN SUITABLE CONTAINER (PLASTIC), FOR LATER
DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:OBSERVE ALL FEDERAL, STATE AND LOCAL
REGULATIONS WHEN STORING THIS SUBSTANCE. FOR ASSISTANCE, CONTACT
DISTRICT DIRECTOR OF THE EPA.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:NONE REQUIRED. USE NIOSH/MSHA APPROVED
RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:NONE REQUIRED.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:EMERGENCY EYE WASH FOUNTAIN IN IMMEDIATE
WORK AREA.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRST AID PROC:CHEMICAL REMAINS (APPROX 15-20 MIN). GET MD IMMEDIATELY.
INGEST:DO NOT INDUCE VOMITING. GET MD IMMEDIATELY.
Chemical Properties
HCC:N1
Vapor Pres:14 (WATER)
Vapor Density:0.7(WATER)
Spec Gravity:1
Evaporation Rate & Reference:>1 (ETHER = 1)
Solubility in Water:COMPLETELY
Appearance and Odor:ORANGE LIQUID.
Stability
Stability Indicator/Materials to Avoid:YES
NONE KNOWN
Stability Condition to Avoid:NONE REPORTED.
Hazardous Decomposition Products:NONE HAZARDOUS
Disposal
Waste Disposal Methods:CHROMIUM-REGULATORY LEVEL:5 MG/L. MATLS WHICH
CONTAIN THIS SUBSTANCE AT/ABOVE REGULATORY LEVEL MEET EPA CHARACT
OF TOX & MUST BE DISPOSED OF I/A/W 40 CFR PART 262. EPA HAZ WASTE
NO.D007. DISPOSE OF I/ A/W FEDERAL, STATE & LOCAL REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.